Threaded outlet tapped outlet.
Drains connecting between podium floors.
7 9 drainage system testing drainage test upon completion of the building drain connection and marriage line crossover connection the drainage system must be rechecked for leaks according to the following.
It works as a structural floor and transfer slab for loads from the above superstructure to the walls and columns below.
Podium slab construction techniques.
Floor and area drains floor drain selection factors pipe connection no hub standard butt connection using no hub or neoprene coupling suitable for cast iron plastic and most other piping applications.
Suitable for no hub or service weight cast iron sch.
The push on drain body and gasket can be utilized with plastic steel no hub and service weight soil pipe.
Yes another apartment building with basement car park beneath water standing on the external deck with some penetration into the basement car park beneath mainly at service penetration positions however the main issue was movement of water through the external wall of the apartments built upon the deck into voids within habitable apartments which housed electrical heating plant.
40 plastic and steel pipe.
If the floor drain connects only to a sump pit it s probably against local ordinances to drain any water that contains detergents salt or chemicals.
Toilet vent option 1.
Remove all access panels to all p traps cleanouts and fixture drain connections inside the walls and floor.
Generally speaking yes and further usually within the confines of the bathroom floor s footprint.
Internally threaded drain connection for joining drain to a threaded pipe drain line with american standard taper pipe threads npt.
The horizontal vent pipe runs right next to the closet.
If the toilet drain does not connect directly to a vent you must find another way to vent it.
Have told us that installing floor drains within a podium system is not easy because of the need to properly accommodate the 3 4 drain board that is typically installed underneath the pavers in podiums.
Functions of podium slab.
Push on p gasket connection astm c 564 with pipe stop.
Floor drains are most often installed during original construction often in the utility area to drain away excess water in the basement.
The unique mifab podium drain solution allows for full flow of water off the drain board into the sump of the drain body.
Push on is a unique labor saving compression gasketed connection designed to simply push on the stub end of the pipe.
The concrete floor around the drain gently.
If the basement floor is lower than the spot where the main sewer line exits the home the floor drain could connect to a third type of drainage system a sewer pit with an ejector pump.